Sign In | Join Free | My chinaqualitycrafts.com |
|
Brand Name : Uchi
Model Number : OBV-II40-5
Certification : CE / SGS / ISO9001
Place of Origin : Dongguan China
MOQ : 200 piece
Price : Negotiate
Payment Terms : T/T, L/C, Western Union
Supply Ability : 60000 pieces per month
Delivery Time : 5-15 days after payment
Packaging Details : export package / Negotiate
Uc : 385V
Condition : 100% Original
CertificationCE,CQC : CE / CQC / SGS
System voltage : 220V
Environment temperature : (-25℃~+80℃)
Status indicator : Green-OK; red-replace
Response time (L-N) : ≤25ns
Protection rating : IP 20
In(8/20μs) : 20kA
Imax(8/20μs) : 40kA
Up : 1.8KV
pole : 4 poles
SPD type : voltage limiting type SPD
4 Poles 40kA Surge Protector Voltage Limiting Type For AC Power System
OBV-II40-5 data:
Uc(maximum continuous operating voltage) | 385V |
Imax(maximum discharge current) | 40kA |
In(nominal discharge current for class II test) | 20kA |
Up(voltage protection level) | ≤1.8kv |
Combination | 1P,2P,3P,4P,1+1;3+1 |
response time | ≤25ns |
Signal deterioration indication | Red: replace Green:ok |
Housing Material | thermoplastic material |
Housing self-extinguishing class | UL94_V0 |
Temperature range | -40℃~+80℃ |
humidity range | 5%RH~95%RH |
Elevational | ≤3000m |
Method of connecting wire | Parallel Connect |
Thread Dimensions | 4~35mm2 |
Mounting method | DIN:35mm |
IP(degree of protection of enclosure) | IP20 |
Follow up standard | IEC 61643-1,GB/T 18802.1 |
Installation Instructions:
(1) surge special circuit breaker or a fuse or circuit breaker must be installed at the front end of the surge protector to prevent the damage of the switching SPD and its lines caused by the power frequency continuous current caused by lightning strike, and to prevent the line fault caused by the increase of leakage current caused by the aging of the voltage limiting devices.
(2) The surge protector must be installed by a professional, and the power supply should be disconnected during installation. Connect the ground terminal first, then connect the other lines.
(3) once the surge protector is installed, do not change the installation position and wiring mode of the product at will, otherwise it will affect the function of the lightning protection system.
Usage:
System voltage limiting surge protector, suitable for installation in 220V/380V(50/60Hz) or 230V/400V(50/60Hz) low voltage power supply and distribution system, It is usually installed in the lightning protection zone LPZ0, LPZ1 or LPZ1, LPZ2, computer room, monitoring machine room, fire fighting machine room, telephone machine room, office and home building power distribution machine room and other weak current machine room. It is designed to protect low-voltage electrical devices from inducted lightning strike and surge harm. This product has the advanced structure design, the high quality material device, the reliable manufacturing process, the excellent safety performance, provides the omni-directional lightning protection for the electrical equipment.
Parameters:
1. SPD Type:voltage limiting type SPD;
2. Maximum Continuous Operating Voltage: 385V
3. Nominal Discharge Current :20KA
4. Voltage Protection Level: 1.8KV
5. Response Time: <25ns
6. Discontinuous Current Capability:no continuous flow
7. Single Stage Width: 18mm
8. Connector Wire Diameter: > 8mm2
9. Operating Status Indicator: window red replacement
The type of SPD:
1. According to the working principle divided:voltage switching type SPD, voltage limiting type SPD , voltage cobination type SPD
2. According to the use of points : power system surge protection device, signal system surge protection device
![]() |
4 Pole AC 40kA Voltage Limiting SPD Surge Protector Images |