Sign In | Join Free | My chinaqualitycrafts.com |
|
Brand Name : Uchi
Model Number : OBV10-I-15
Certification : CE / SGS / ISO9001
Place of Origin : Dongguan China
MOQ : 200 piece
Price : Negotiate
Payment Terms : T/T, L/C, Western Union
Supply Ability : 60000 pieces per month
Delivery Time : 5-15 days after payment
Packaging Details : export package / Negotiate
DC : 1000V
CertificationCE,CQC : CE / CQC / SGS
System voltage : 500/600VDC
Operating temperature : (-40~+85°C)
Normal discharge current(8/20μs) : 20kA
Status indicator : Green(good)/red(need replacement)
Response time (L-N) : ≤25ns
Protection class : IP20
Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules
Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)
Tried and tested fault-resistant Y circuit of the OBV5-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuit
Integrated d.c. fuse allows safe replacement of protection modules without arc formation.
Application:
Advantage:
Model: OBV5-C40-PV series | ||||||
Network voltage | 500Vdc | 600Vdc | 800Vdc | 900Vdc | 1000 Vdc | 1200V |
Max. operating voltage Uc | 530Vdc | 630Vdc | 840Vdc | 950Vdc | 1060 Vdc | |
Nominal discharge current ln | 20kA | |||||
Max. discharge current lmax | 40kA | |||||
Protection level (at In) Up | 1.8kV | 2.5kV | 2.8kV | 3.0kV | 3.2kV | |
Disconnector | ||||||
Thermal Disconnector | Internal | |||||
Mechanical characteristics | ||||||
Dimensions | See diagram | |||||
Connection | by screw terminals: 4-25 mm2 | |||||
Disconnection indicator | 1 mechanical indicator by pole | |||||
Mounting | symmetrical rail 35 mm | |||||
Operating temperature | -40/+85°C | |||||
Protection class | IP20 | |||||
Standards compliance | ||||||
NF EN 61643-11 France | Parafoudre Basse Tension - Essais Classe II | |||||
IEC 61643-1 International | Low Voltage SPD - Test Class II | |||||
EN 61643-11 Europe | Parafoudre Basse Tension - Essais Classe II |
Feature:
1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715
5,It can effectively ensure the equipments work properly
Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) |
Max Discharge Current Imax(KA) |
Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 |
275/320 385/420 |
5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
![]() |
GPS Antennas PV Surge Protector , Thunder Lightning Protection Device Images |